After the valve was placed in the upper position on the pipeline, the handle and thermometer were connected, the water pressure was very low. I turned off the main water and removed the cartridge, then turned the main water back on, I had good pressure. Hoping some dirt would come out in the valve, I put the cartridge back into the low pressure valve. I bought and installed another cartridge but to my dismay the pressure is low again. I removed the cartridge while the water was pressurized. I shut off the water supply and reinstalled a new cartridge and low pressure. I tend to think the valve is defective or I'm doing something wrong. Open to any suggestions.