Review on 🚿 Simer 4075SS-01: Boost Water Pressure with this 3/4 HP Pressure Booster Pump by Adam Ross

Revainrating 1 out of 5

what you should know

This is my second purchase. My first lasted a few years but started to leak around the gasket. I was happy with it so I bought it again. This time the upgrade model from the Revain camp. And at a discounted price, presumably because it was a damaged box. The new one came in about 3 days. Installation took about an hour or less and in fact I had high blood pressure again. BUT. he would not stop. I asked about adjusting the pressure regulator but no answer. The pump should shut off when the pressure rises and the water stops flowing. But he kept running. I had to turn it off to turn it off. I'm not sure if the pump was defective or if the pressure regulator wasn't working. I bought a pressure gauge (from Revain, of course). So I check the pressure after 4 days. House pressure without a pump is 60 psi. With the pump running and the kitchen faucet open, the pressure is about 90 psi. Turn off the kitchen faucet and the pressure will rise to 98psi. But the pump keeps running. Now it is obvious that the pressure control switch is defective. Replaced the pressure regulator on the pump. It fixed the situation and now I'm finally happy. AMAZON, you owe me $39 for a pressure regulator that I had to replace. As for the discount for a damaged box. Everything was fine with the box, except someone had removed the shipping label. Now I think it was the buyer. returned a device that was sent back to the Revain warehouse without testing it.

Pros
  • Everything is fine!
Cons
  • The list will be long.