My 30 year old F20T12 single tube fluorescent light bulb just started to heat up the filaments but the tube never ignited. Tried a new tube but got the same results so I knew the ballast was bad. Once I had this ballast I opened up the bracket and found the original Advance ballast which was MUCH larger and heavier than its smaller and lighter replacement. The wiring for the new one was slightly different as previously a clamp on one end of the tube and the white wire to the old ballast were connected to a 120V neutral power supply. The new ballast has two red wires for the clamps on one end of the tube, two blue wires for the terminals at the other end, and black and white wires for 120V hot and neutral power respectively. Easy to install and it worked great!