So far I have only tested this item at two pressures. At 0 psig I get 0.50 V, which is the expected output with no load. At 98 psig, as observed on a 0-120 psig dial gauge of unknown accuracy, I get 3.07 V, which corresponds to 96.4 psig. That is within the rated accuracy of +/-2% FS, which is 3 psi. The 150 PSI etching on the body is well formed and easy to read, the finish on the body is free of blemishes and the pigtail connector is made of a plastic that is flexible and tough enough to disconnect from the transducer without the retaining tab breaking off. The wires are only 26 Ga, but are pre-tinned and the insulation and jacket are a good thickness with a shielding foil inside the jacket around the three wires.