I have never attempted to adjust this switch myself. If so, you would immediately see three problems: The two screws that attach the cover to the switch mechanism are metric threads and will not fit the weatherproof (or steel) boxes available in America that have 6/32 screw threads. .- The switch mechanism is too deep to fit in a standard 2" deep weatherproof box without modification.- The plastic cover is too soft - if you overtighten the mounting screw it will sink into the cover itself. On the positive side, that it's not expensive, I was able to install it and it works.No doubt there are many other ways to install this switch than I did.Metal box is stronger than plastic.You will need a metal "weatherproof box extension" though, to actually fit the switch (available from Revain/Lowes/Home Depot etc.) 1" deep on the box to allow room for this switch and its wiring. Attach the extension to the weatherproof box using the 4 provided #6/32 x 1.25" screws. Route the wires through the appropriate electrical connectors/terminals screwed into the threaded holes (holes) of the box attach secure the (metal) case to the instrument with two or three bolts/nuts. Remove the two switch bolts, lock washers and nuts and replace them with 6/32 1" long bolts with small washers to relieve the pressure on the soft cover of the switch Attach the ground wire to the box's green metal screw (if it's a plastic box, just cover the ground wire) The switch itself isn't grounded as it's plastic case will get hot (110 V) or hot (220V) to the LINE terminal(s) and the tool lead(s) to the corresponding LOAD terminal(s) Screw the switch and cover g onto the box extension with 1" #6 machine screws (with washers). See photo for installing this switch.
🔌 Interlock Kit for Generators with Cover and QOM2 Frame Size Main Breaker Interlock Kit
8 Review
🔌 GE 150 or 200 Amp Main Breaker Generator Interlock Kit - 1 1/4 Inch Spacing Between Main and Branch Breaker
7 Review
Electricity Monitor Voltage Overload Protection
8 Review
💡 Professional Generator Interlock Kit: Compatible with Square D QO or Homeline 150/200 Amp Panels, 1 3/8" Spacing Between Main and Generator Breaker
7 Review
🔌 Robertson 2P20132 Quik-Pak: 10 Fluorescent eBallasts for 2 F40T12 Linear Lamps, Preheat Rapid Start, 120Vac, 50-60Hz, Normal Ballast Factor, NPF, Model RSW234T12120 /A (Crosses to RSW240T12120 /B)
4 Review
💡 Electronic FL Ballast ICN-4P32-N (Formerly ICN-4P32-SC) for 3-4 F32T8 F40T8 F17T8 Lamps, 120V/277V Compatibility
5 Review
⚡️ Sunpark LC-12014T (1) FC12T9 32W Circline (1) 2D 38W (1) FC16T9 40W Circline (1) FC9T9 30W Circline Lamp Compact Electronic Fluorescent Ballast with Circline Lamp Plug 120V
7 Review
Wireless Electronic Ballast Interface Certified
8 Review