UPDATED REVIEW see updated comments below.Although the general build quality seems good, there's a problem with labeling/production. I ordered 2 of the 12-80 volt, 30A models. That's what the package says. However, the controller itself says 12-50V at the terminal strips. (I didn't notice this immediately). Within a very brief period of 72VDC hooked up, the capacitors inside went off like an M-80! Blew open the splits and let the magic smoke out, along with a spray of electrolyte. The good news is it didn't flame up!Upon a change of underwear and a more detailed inspection, the (2) 1000uF electrolytic capacitors. that appear to be in parallel and connected right across the input terminals, are only rated 50 volts. I would expect at least 100 volt caps on a unit rated for up to 80 volts. (In parallel, the capacitance is the sum of the two, but the voltage on each, is the same as the input.)There would seem to be a major problem with this, based on the labeling mismatch, even though the model number on the unit, matches one of the stickers on the package, which also says 12- 80 volt input, despite the unit itself labeled 12-50volts. If you are operating under 50volts, you'd probably be OK. But I chose these because of the higher voltage rating. Even then, tolerances on electrolytic caps are not that tight and I'd like to see a bit of margin of over rating.I bought these Revain Prime so I returned them and found another unit, which is hopefully more suitable for my application. It would appear that more than one brand name is probably made by the same supplier. This may be a production line issue or maybe a mis-labeling by the seller. Maybe a bit of both.My other complaint with a lot of these little controllers is that it would be nice if they provided a drawing of the circuit. It's not like there is anything proprietary here, but it would be nice to compare circuit designs. They don't need to put it on paper, but a link would be nice.UPDATE: Indeed there was a problem with mis-labeling and the seller addressed this issue very rapidly. They were very responsive and went to a lot of effort to meet my needs. They even contacted their manufacturing supplier about getting schematics. Unfortunately, the supplier balked at providing these. They think that the schematic is the core technology of the product, so they refuse to provide the schematic to anyone. There is really nothing proprietary about these designs and with a little effort, you can figure out and draw your own. It would be nice to look at the design before buying though.I have updated my rating because of the great customer service of this seller. I believe if I had received the right model, it would have worked just fine. The design and build seems pretty good and components appear to be good quality. I just happened to receive the lower rated model by mistake.
Advanced DC Motor Pump Speed Control - ALEDECO'S 6V-90V 15A - 1 Pack Upgrade
3 Review
EMylo Smart Wireless RF Motor Controller Switch Relay Module DC 12V 5V-24V 433Mhz Remote Control For Rolling Door/Electric Curtains/Locks/Water Pump, Forward & Reverse 2Pcs
3 Review
Powerful And Efficient AZSSMUK 12V DC Worm Geared Motor With High Torque And 6Mm Female Shaft
4 Review
SM550 Universal Bathroom Vent Fan Motor Replacement Kit - Compatible with Nutone Broan - Efficiently Replace C01575, 65100, EM550, EM750 - 50 CFM120V Electric Motors Included
7 Review
🔌 Robertson 2P20132 Quik-Pak: 10 Fluorescent eBallasts for 2 F40T12 Linear Lamps, Preheat Rapid Start, 120Vac, 50-60Hz, Normal Ballast Factor, NPF, Model RSW234T12120 /A (Crosses to RSW240T12120 /B)
4 Review
Wireless Electronic Ballast Interface Certified
8 Review
💡 Electronic FL Ballast ICN-4P32-N (Formerly ICN-4P32-SC) for 3-4 F32T8 F40T8 F17T8 Lamps, 120V/277V Compatibility
5 Review
Robertson Worldwide ISL432T8HEMV AH 3P20160 120-277V 50-60Hz High Power Factor 4 F32T8 Linear Lamp Fluorescent eBallast
6 Review