Firstly, reviewers who claim you would be shocked by this should not use a meter or contact messing around with the electrics In general their claims are absolutely ridiculous. To my actual assessment. I use this 100 times a day, every day, so I've had plenty of time to familiarize myself with it on everything from 3 volts to 480 3 phase. The field sensor's voltage measurement was a key selling point for me, oddly enough I found it a useless feature after using it. I just use my Fluke 1AC-A II VoltAlert more effectively. To be honest I suppose someone can use it. In my job, I just need to know if there is voltage, or I need to read the combined voltage at more than one point. The voltage on a wire doesn't tell me much. It's not entirely accurate either, when in use it can tell me 139VAC on the wire and when I use the sensors I actually get a reading on the same 119VAC wire. If you are testing devices for 208VAC it will not read 208V, it will still only read 120VAC with one wire. If they could make it so I could feel a full 208VAC on a heater wire for example, that feature would be a game changer, but at least it's not useless to me. I used my old T5-600. For so many years that it feels like a natural part of my body to carry it in my back pocket, the new T6-600 is a bit thicker and takes some getting used to, the plastic itself doesn't seem as durable as the old T5-600, that has withstood years of abuse and falls from the stairs. The new one didn't break, but it just doesn't feel as solid. The field amperage reading works great, as it always did with the old T5-600, and I'd probably send it back and just use my trusty T5-600 if it weren't for the backlit display on this new T6-600, which is a much-needed feature T5-600 sorely lacked. My conclusion: If the old T5-600 had a backlit display, I would say you have a win-win choice of buying the T5-600. The new T6-600's field measurement function is clearly not a very useful gimmick unless you can use it to read actual voltages on a single wire of 208, 240 and 480 VAC. I could actually use this function to know when the thermostat is turning on and off in the 208VAC heating element circuit without removing the wire nuts as that's a useless gimmick now.
12X9X3 Inch Granite Surface Plate With No Ledge - Perfect For Precision Measurement
9 Review
Car seat JUNION Ebby group 0+/1/2/3 (0-36 kg), Isofix, dark gray
13 Review
β‘ Pro Fluke T6 1000 Electrical Tester for Enhanced SEO
5 Review
Enhanced Performance: Fluke BP190 Rechargeable Capacity ScopeMeter - Revolutionizing Test and Measurement Efficiency
5 Review
π¬οΈ Advanced 3-in-1 Indoor Air Quality Monitor with CO2/RH/Temp Data Logging and Audible Alarm - NDIR Sensor Technology
8 Review
π Enhanced Precision with Backlit Professional Manometer for Differential Ventilation
6 Review
π Dioxide Controller for Digital Gas Monitoring
5 Review
Digital multimeter RGK DM-12
6 Review