OK - - So it's 9pm and the pump is still running. It was supposed to shut down at 7:00 p.m. The LED on the control panel is off, so the contactor must not be switched on. I disconnected the control cable from the panel to check - and sure enough - the pump kept working. I disconnected the 240v section of the panel (flip the switches) and removed the contactor from that pump. I opened it up and you can see the contactor's fusible contacts glued to the corresponding contacts on the other side. Anyway, the reason I posted this was to resolve part number confusion! Omron has removed the letters "IN" from the end of the contactor part number. Picture 2 shows the contactor part number I removed: G7L-2A-BUBJ-CB-IN. The NEW part number completely eliminates any reference to IN and is listed as G7L-2A-BUBJ-CB.