Header banner
Revain logoHome Page
πŸ’₯ enhanced control devices cs25 100 start valve for optimal performance logo

πŸ’₯ Enhanced Control Devices CS25 100 Start Valve for Optimal Performance Review

3

Β·

Excellent

Revainrating 5 out of 5Β Β 
RatingΒ 
5.0
πŸ”§ Fittings, 🚰 Hydraulics, Pneumatics & Plumbing

View on AmazonView on Π―M

Media

(2)
img 1 attached to πŸ’₯ Enhanced Control Devices CS25 100 Start Valve for Optimal Performance
img 2 attached to πŸ’₯ Enhanced Control Devices CS25 100 Start Valve for Optimal Performance

Description of πŸ’₯ Enhanced Control Devices CS25 100 Start Valve for Optimal Performance

Cold start valves bleed air from the compressor head during start up reducing start up torque requirements. Valve closes at 25 psi. Valve closes with 2.5 SCFM flow. Item Package Dimension: 4.0" L x 3.0" W x 1.0" H.

Reviews

Global ratings 3
  • 5
    3
  • 4
    0
  • 3
    0
  • 2
    0
  • 1
    0

Type of review

Revainrating 5 out of 5

Port Cargo Compressor works now!

Harbor Freight McGraw supercharger weighing 135 pounds, I believe that's its name. in any case, the cylinder pressure was vented from the head as intended when the supercharger shuts down, but the cold start valve seemed undersized or defective as the supercharger failed to start under load. I bought a 1/4" tee and 2 of those cold start valves and now the supercharger I got for half price ($101) has been remanufactured for an additional $16!

Pros
  • Industrial & Scientific
Cons
  • Questionable purchase for the elderly

Revainrating 5 out of 5

Did the trick! Best with Check Valves

Use this with my Harbor Freight 21 gallon air compressor that refused to start unless the tank was empty. I took out the stock cold start valve and replaced it with a 1/4" NPT tee, then put the stock valve in the tee and this from Revain. Now with two valves, the compressor can be started with compressed air in the tank , as two valves let it accelerate to full speed without simultaneously driving against an air load and accelerating from zero to full speed - that's what it takes to finally…

Pros
  • Valves
Cons
  • Scarce Manual

Revainrating 5 out of 5

My compressor starts at 20 below with this

Very useful piece of equipment. I have a high quality Makita compressor that I am forced to use with a tremendous voltage drop in facilities where temperatures are well below freezing. The only way I got my compressor to start earlier in these situations was to completely empty the tank before starting, and when I ran 15 minutes without turning on the compressor, empty it again. I use 3 of these in a small manifold that I attached to my compressor's unloader. Even with a full tank, they will…

Pros
  • Hydraulics, Pneumatics and Plumbing
Cons