Out of service after 1 season. Examination of the inner braided copper wire showed noticeable discoloration at the junction of the bimetallic strip. The normal current draw from the AC line was 29A, so this error was probably caused by a high resistance at this connection point. The current path on side A was measured at 0.5 ohms while the other was about 2.5 ohms, so I concluded that the bimetal connection with the braided wire on side B was failing. I installed a new UBIF260N, I hope this one lasts longer.
π Bussmann GMA 5A Acting Cartridge Listed: Reliable and Efficient Cartridge Fuse for Your Automotive Needs
7 Review
Square HOMT2020 Circuit Breaker Homeline
7 Review
π Enhance Your Electrical Work with Klein Tools 69411 Accessory Adapters
7 Review
Acoustic system BEHRINGER Eurolive B115D black
11 Review
Vacuum cleaner KARCHER VC 3, yellow
176 Review
5Pcs 19Mm 12V 24V Waterproof Latching Push Button Switch With Wiring Harness And LED Indicator Light, Pre-Wired SPDT Self-Locking 4 Pin Marine Metal Switch For Boats Cars Trucks (Blue)
22 Review
Adjustable Regulator Generator PEMENOL Controller
9 Review
TWTADE/AC 24V 10A Coil Electromagnetic Power Relay 8 Pins 2DPT 2NO+2NC With Indicator Light And Socket Base -YJ2N-LY
9 Review