In case anyone is having trouble understanding the instructions, here is what I assembled and installed for the heating element. USP = Upper Set Point LSP = Lower Set Point of HY1 and HY2 Hysteresis – How far the temperature can go, for example: set the temperature to 100 and HY to 1 and it won't adjust until the temperature reaches 102 DP – Decimal point Scy – Latch - skip itPuF - set temperature offsetInp - enter TypeP - proportional band, interval setting, leave at 1I - Inverval, 540x per second - Derivative - forecast future demand. required for electronic relay C - F Celsius or Fahrenheight AL01 & AL02 = Alarms A01 and A02 - leave on 2, there are 7 settings but not used for heater hold SetUSP = 214LSP - SkipHY1 = 1HY2 = 1DP = 0Scy - SkipAl1 =300A01 = 2Al2 = 300A02 = 2PUF = 4.5 - Calibrated to be the top of my kettle Inp = Try each one until you find one that works for your sensor.