πŸ’‘ Siemens ECSBPK03 Standby Power Mechanical Interlock for Generators Review

3

Β·

Average

Revainrating 3.5 out of 5Β Β 
RatingΒ 
3.7
πŸ”Œ RV Power & Electrical Parts, 🚐 RV Parts & Accessories

View on AmazonView on Π―M

Media

(4)
img 1 attached to πŸ’‘ Siemens ECSBPK03 Standby Power Mechanical Interlock for Generators
img 2 attached to πŸ’‘ Siemens ECSBPK03 Standby Power Mechanical Interlock for Generators
img 3 attached to πŸ’‘ Siemens ECSBPK03 Standby Power Mechanical Interlock for Generators
img 4 attached to πŸ’‘ Siemens ECSBPK03 Standby Power Mechanical Interlock for Generators

Details

BrandSiemens
Item Dimensions LxWxH16.6 x 7.6 x 6.5 inches
Item Weight0.25 Pounds
ColorClear Chromate

Description of πŸ’‘ Siemens ECSBPK03 Standby Power Mechanical Interlock for Generators

Ensures the main breaker within a panel is forced to the off position when standby power is on. For use on Siemens or Murray panels that are 150, 200, or 225 amp, ultimate or rock solid type. Standby power breaker must be a QP or MP double pole breaker. Adds an extra level of safety. No modification of panel required; Breakers not included.

Reviews

Global ratings 3
  • 5
    1
  • 4
    1
  • 3
    0
  • 2
    1
  • 1
    0

Type of review

Revainrating 4 out of 5

fits my load center Siemens G4040B1200

The metal used on this lock is a bit flimsy and flimsy and I don't believe this item was actually made by or for Siemens. it simply fits on the Siemens load center. Unlike my signature Eaton lock for another house, this is a thick plate of powder-coated steel. Regardless, he's doing his job. A few installation notes: (1) The load center cover does NOT need to be cut - move the main and generator breaker locking slides to the off position and the cover will slide off immediately; (2) The…

Pros
  • Emergency power switch must be a QP or MP bipolar switch
Cons
  • Long delivery time

Revainrating 2 out of 5

Overpriced but yes it works

Firstly I'm sure they are made in China for less than a dollar but they have short hair. Second, the statement is lame. And yes, you will lose the top two right switch positions unless you change the lock. To install this unit, make sure that the panel cover area between the main switch and the top left switch (generator input) is flat or even slightly concave towards the wall). Snap the latch on the generator input switch into place (install the wires first) and insert the small screw into the

Pros
  • Adds an extra layer of security
Cons
  • There are cons

Revainrating 5 out of 5

Works great / easy to install

Lock works exactly as intended. No changes required. Parts must not be modified in order to maintain UL approval.” It was used on my Siemens P4080B1200ACU panel along with the Siemens Q230 Type QP circuit breaker and Siemens ECMBR2 mounting kit. Note that the ECMBR2 mounting kit requires a 60 amp or larger breaker for the electrical screw cover to engage. Lower current switches do not have latches that capture the black edge of the cover. In my opinion, operation without this cover is…

Pros
  • No panel modification required; Switch not included
Cons
  • I will add later